Product Description for Link-A-Light FluoProbes682 Conjugation Kit

Product is tested for Labeling.

Properties for Link-A-Light FluoProbes682 Conjugation Kit

Product Category Labeling Kits & Reagents
Quantity 1 kit
Reaction 1 labeling reaction, 1-2 mg
Conjugate FluoProbes682
Applications Labeling
Shipping to Worldwide
PDF datasheet View Datasheet
Manufacturer Acris Antibodies GmbH
Material safety datasheet MSDS for Link-A-Light FluoProbes682 Conjugation Kit

Datasheet Extract

Application Conjugation.
Background The Link-A-Light conjugation kit allows Fluorescent conjugations to set up in seconds, simply by adding a solution of the antibody to be labeled to a proprietary lyophilised mixture containing a proprietary activated Fluorescent Ligand (Figure 1).
By circumventing the desalting or dialysis steps that commonly interrupt traditional protein conjugation procedures, Link-A-Light technology can be used to label small quantities of protein (see Principle).
Label: FluoProbes682 is one of a new generation of Fluorescent labels designed to label biomolecules. It has a strong absorbance between 620 and 690nm, high fluorescence at 709nm and high quantum yield. FluoProbes682 can be used as a substitute dye for Cy5.5, WellRED D3-PA, LightCycler RED 705, DY-681 and Alexa Fluor 680.
Protocols 1. Before you add antibody to the Link-A-Light Mix, add 1 µl of Link-A-Light Modifier reagent for each 10 µl of Antibody to be labeled. Mix gently.
2. Remove the screw cap from the vial of Link-A-Light Mix and pipette the antibody sample (with added Link-A-Light Modifier) directly onto the lyophilised material. Resuspend gently by withdrawing and re-dispensing the liquid once or twice using a pipette.
3. Place the cap back on the vial and leave the vial standing for 3 hours at room temperature (20-25°C). Alternatively, and sometimes more conveniently, conjugations can be set up and left overnight, as the longer incubation time has no negative effect on the conjugate.
4. After incubating for 3 hours (or more), add 1 µl of Link-A-Light Quencher FD reagent for every 10 µl of antibody used. The conjugate can be used after 30 minutes.
Storage Storage of Conjugates: For any new conjugate, initial storage at 4°C is recommended. A preservative may be desirable for long-term storage. Other storage conditions (e.g. frozen at -70°C or stored at -20°C with 50% glycerol) may also be satisfactory. The best conditions for any particular conjugate must be determined by experimentation.

Storage of Kit: The kit is shipped at ambient temperature in a tamper-evident polypropylene container. Store at -20°C upon receipt.