AC039-004 Link-A-Light PE-Texas Red Conjugation Kit (1 labeling reaction)

Search for all "Link-A-Light PE-Texas Red Conjugation Kit"

1 x 1 mg / €530.00


More Views

  • AC039-004

Product Description for Link-A-Light PE-Texas Red Conjugation Kit

Product is tested for Labeling.

Properties for Link-A-Light PE-Texas Red Conjugation Kit

Product Category Labeling Kits & Reagents
Quantity 1 x 1 mg
Reaction 1 labeling reaction
Conjugate PE-Texas Red
Applications Labeling
Shipping to Worldwide
PDF datasheet View Datasheet
Manufacturer Acris Antibodies GmbH
Material safety datasheet MSDS for Link-A-Light PE-Texas Red Conjugation Kit

Datasheet Extract

Application Conjugation.
Background Link-A-Light is a one step antibody labeling kit, requiring just 30 seconds hands-on time. The antibody is covalently bonded to the label in a directional and controlled process at near-neutral pH.
The Link-A-Light conjugation kit allows PE-Texas Red Tandem conjugations to set up in seconds, simply by adding a solution of the antibody to be labeled to a proprietary lyophilised mixture containing PE-Texas Red (Figure 1).
By circumventing the desalting or dialysis steps that commonly interrupt traditional protein conjugation procedures, Link-A-Light technology can be used to label small quantities of protein for FACS analysis with 100% recovery (see Principle).
Label: PE-Texas Red is a Tandem conjugate. The PE is excited at 535nm and functions as an energy donor for the Texas Red. Energy is transferred from the PE to the Cy5.5 via Fluorescence Resonance Energy Transfer (FRET). The Cy5.5 emits the energy received from the PE in the form of long wavelength light at 615nm.
Protocols 1. Before you add antibody to the Link-A-Light Mix, add 1 µl of Link-A-Light Modifier reagent for each 10 µl of Antibody to be labeled. Mix gently.
2. Remove the screw cap from the vial of Link-A-Light Mix and pipette the antibody sample (with added Link-A-Light Modifier) directly onto the lyophilised material. Resuspend gently by withdrawing and re-dispensing the liquid once or twice using a pipette.
3. Place the cap back on the vial and leave the vial standing for 3 hours at room temperature (20-25°C). Alternatively, and sometimes more conveniently, conjugations can be set up and left overnight, as the longer incubation time has no negative effect on the conjugate.
4. After incubating for 3 hours (or more), add 1 µl of Link-A-Light Quencher FD reagent for every 10 µl of antibody used. The conjugate can be used after 30 minutes.
Storage Storage of Conjugates: For any new conjugate, storage at 4°C is recommended. A preservative may be desirable for Long-term storage. Other storage conditions may also be satisfactory. The best conditions for any particular conjugate must be determined by experimentation.

Storage of Kit: The kit is shipped at ambient temperature in a tamper-evident polypropylene container. Store at -20°C upon receipt.