discontinued

AC045-002 Link-A-Light Streptavidin Conjugation Kit (3 labeling reactions)

Search for all "Link-A-Light Streptavidin Conjugation Kit"

3 x 100 µg / €340.00

AC045-002

Product Description for Link-A-Light Streptavidin Conjugation Kit

Product is tested for Labeling.

Properties for Link-A-Light Streptavidin Conjugation Kit

Product Category Labeling Kits & Reagents
Quantity 3 x 100 µg
Reaction 3 labeling reactions
Conjugate Streptavidin
Applications Labeling
Shipping to Worldwide
PDF datasheet View Datasheet
Manufacturer Acris Antibodies GmbH
Material safety datasheet MSDS for Link-A-Light Streptavidin Conjugation Kit

Datasheet Extract

Application Conjugation.
Background Link-A-Light is a one step antibody labeling kit, requiring just 30 seconds hands-on time. The antibody is covalently bonded to the label in a directional and controlled process at near-neutral pH.
The Link-A-Light conjugation kit allows Streptavidin conjugations to be set up in seconds, simply by adding a solution of the antibody of the protein to be labeled to a proprietary lyophilised mixture containing a proprietary activated Streptavidin Ligand (Figure 1).
By circumventing the desalting or dialysis steps that commonly interrupt traditional protein conjugation procedures, Link-A-Light technology can be used to label small quantities of protein with 100% recovery (see Principle).

Label: Streptavidin is a 53kDa protein purified from Streptomyces avidinii, which has widespread applications due to its very high affinity to the vitamin biotin.
Streptavidin is a tetrameric molecule, composed of 4 13kDa monomers, each of which can bind a molecule of Biotin.
Protocols 1. Before you add antibody to the Link-A-Light Mix, add 1 µl of Link-A-Light Modifier reagent for each 10 µl of Antibody to be labeled. Mix gently.
2. Remove the screw cap from the vial of Link-A-Light Mix and pipette the antibody sample (with added Link-A-Light Modifier) directly onto the lyophilised material. Resuspend gently by withdrawing and re-dispensing the liquid once or twice using a pipette.
3. Place the cap back on the vial and leave the vial standing for 3 hours at room temperature (20-25°C). Alternatively, and sometimes more conveniently, conjugations can be set up and left overnight, as the longer incubation time has no negative effect on the conjugate.
4. After incubating for 3 hours (or more), add 1 µl of Link-A-Light Quencher FD reagent for every 10 µl of antibody used. The conjugate can be used after 30 minutes.
Storage Storage of Conjugates: For any new conjugate, storage at 4°C is recommended. A preservative may be desirable for Long-term storage. Other storage conditions (e.g. Frozen at -70°C or stored at -20°C with 50% Glycerol) may also be satisfactory. The best conditions for any particular conjugate must be determined by experimentation.

Storage of Kit: The kit is shipped at ambient temperature in a tamper-evident polypropylene container. Store at -20°C upon receipt. Shelf life: one year from despatch.